Failure codes as three lists: problem, cause and remedy
A common scheme has three lists, each picked from when a repair work order is closed: the problem (what was seen), the cause (why it happened) and the remedy (what was done). Some schemes add a fourth for the component that failed, such as bearing, seal or belt.
ExampleOne closed job, coded
| What the technician wrote | Code | |
|---|---|---|
| Problem | Pump P-4 seal dripping steadily, puddle at the base | LEAK |
| Cause | Seal faces scored; the pump had been run dry when the tank was drained | USE |
| Remedy | Replaced the mechanical seal | REPLACE |
The note is still the most useful thing for the next technician. The three codes are what let you count.
A starter list of 8 cause codes
USE is not “operator error”: it says the equipment was run outside its design, and the next question is why that was easy to do.
Start with the cause list
Say a crew of four closes 40 repairs a month (a made-up figure). Spread over 60 cause codes, nothing stands out; over 8, a cause with 10 of the 40 jobs is impossible to miss. If you keep only one list, make it cause: it is the one that points at a fix.
ISO 14224, the reference taxonomy
The international reference is ISO 14224 (2016 edition), on reliability and maintenance data, written for the petroleum, petrochemical and natural gas industries. Problem, cause and remedy codes are a simpler version of its scheme.
As a public summary by its technical editor sets out, its failure data separates the failure mode, mechanism, cause and detection method, and its maintenance data records what was done.
How a small team uses them
Pick the cause code when the repair is closed, while the technician still remembers. Once a month, count codes by asset: the same cause on the same asset three times is a candidate for a root cause analysis, and a code climbing across many assets points at a routine.
Codes also explain a falling MTBF, and they only work if work orders are closed with words in them.
Failure codes in Maintensor: a closing note as the stopgap
Maintensor has no failure codes, and a work order has no cause or remedy field. Categories on a work order, such as Electrical, Mechanical or HVAC, group work for filters and Reporting, but they are not failure codes: nothing asks for one when a job closes.
The stopgap is a note added when the job is closed that starts with the code (“LUBE: gearbox low on oil, fill plug loose”), which the work order’s History keeps. Search does not read notes, so the monthly count is done by reading each asset’s finished work orders.