The checks, room by room
One sheet per vacant unit. The technician works through the rooms and fixes what fails, and someone else does the final walk at the end. Add your appliance makers’ instructions, your property’s finish standard (paint colors, flooring, fixtures) and your local rules.
Entry and living areas7 checks
- Entry door opens, closes and latches; weatherstrip and threshold intact
- Deadbolt and knob lock from both sides; door viewer clear
- Walls and ceilings
- Floors
- Lights, switches and outlets; cover plates on
- Closet doors and shelves
- Blinds
Kitchen and appliances9 checks
- Refrigerator on an appliance thermometer after a few hours closed
- Range: each burner, oven bake and broil; knobs present
- Range anti-tip bracket
- Dishwasher: run a short cycle
- Sink, faucet and disposal; look under the sink
- Range hood fan and light
- Cabinets and drawers
- Countertop, backsplash and sink caulk
- GFCI outlets near the sink: press Test, then Reset
Bathrooms8 checks
- Toilet: flush three times, check the base and tank
- Sink, tub and shower: flow, drains, hot water
- Hot water temperature at the tap, on a thermometer
- Caulk and grout around the tub or shower
- Exhaust fan (hold a tissue to the grille)
- GFCI outlet
- Mirror, cabinet, towel bars, grab bars where fitted
- Floor around the toilet and tub
Bedrooms and closets4 checks
- Door closes and latches; privacy lock if fitted
- Windows open, stay open and lock; screens intact
- A bedroom window that serves as the emergency way out
- Outlets, lights and closet
Heating, cooling and water heater6 checks
- Heat: run it until every room warms
- Cooling: supply air clearly cooler than the room
- Filter replaced, with the date written on the frame
- Condensate drain and pan
- Thermostat responds; batteries new
- Water heater in the unit: fittings, relief valve discharge pipe, the space around it
Smoke and carbon monoxide alarms3 checks
- Each smoke alarm: press the test button; read the date of manufacture on the back
- Each carbon monoxide alarm, in units with fuel-burning appliances or an attached garage
- Test written down: date, unit, alarm, who tested
Windows, doors and locks4 checks
- Every window: lock, balance, screen, glass
- Patio or balcony door: slides, locks, security bar
- Balcony railing
- Exterior door locks rekeyed or cylinders changed; new keys and mailbox key logged
Final walk6 checks
- Every line above passed, or has an open work order with a date
- Clean throughout, including inside appliances, cabinets, light fixtures and window tracks
- Photos of every room for the move-in record
- Utilities on, thermostat set, hot water at the taps
- Keys, fobs and remotes counted
- Signed off by someone who did not do the work
What counts as a fail, check by checkThe full tables, room by room.
A check fails when the item does not work, is damaged beyond normal wear, or is unsafe.
Entry and living areas
| Check | Fail if |
|---|---|
| Entry door opens, closes and latches; weatherstrip and threshold intact | Drags, will not latch, or daylight shows around it |
| Deadbolt and knob lock from both sides; door viewer clear | Bolt does not throw fully, lock loose, viewer missing |
| Walls and ceilings | Holes, nail pops, or a stain that may be a leak (find the source before painting over it) |
| Floors | Tears, burns, lifted seams, soft spots underfoot |
| Lights, switches and outlets; cover plates on | Dead outlet, cracked or missing plate, flickering fixture |
| Closet doors and shelves | Door off its track, rod or shelf pulling out |
| Blinds | Broken slats, or a loose cord loop within a child’s reach |
Kitchen and appliances
| Check | Fail if |
|---|---|
| Refrigerator on an appliance thermometer after a few hours closed | Above 40°F (4°C) in the fridge or above 0°F (-18°C) in the freezer, the figures the FDA gives; torn door gasket |
| Range: each burner, oven bake and broil; knobs present | A burner will not light or heat; any gas smell (shut it off, call the gas utility) |
| Range anti-tip bracket | Missing, or the range leg not seated in it. The CPSC says the bracket can save a child from serious injury or death when a range tips |
| Dishwasher: run a short cycle | Leaks, does not drain or does not heat |
| Sink, faucet and disposal; look under the sink | Drip at the trap or supplies, disposal jams or hums |
| Range hood fan and light | Fan dead, filter caked with grease |
| Cabinets and drawers | Water damage under the sink, broken hinge, drawer off its slides |
| Countertop, backsplash and sink caulk | Burns, chips, open seams, missing caulk |
| GFCI outlets near the sink: press Test, then Reset | Power does not cut, or will not reset |
Bathrooms
| Check | Fail if |
|---|---|
| Toilet: flush three times, check the base and tank | Runs on, rocks, leaks at the base or the supply |
| Sink, tub and shower: flow, drains, hot water | Slow drain, drip, hot water slow to arrive |
| Hot water temperature at the tap, on a thermometer | Above 120°F (49°C) from the unit’s own water heater, the setting the CPSC recommends; on a central plant, above its mixing valve setting |
| Caulk and grout around the tub or shower | Gaps, mold that will not clean off, soft wall behind the tile |
| Exhaust fan (hold a tissue to the grille) | Dead, or does not draw |
| GFCI outlet | As in the kitchen |
| Mirror, cabinet, towel bars, grab bars where fitted | Loose, cracked or rusted |
| Floor around the toilet and tub | Soft spots, stains, lifted vinyl |
Bedrooms and closets
| Check | Fail if |
|---|---|
| Door closes and latches; privacy lock if fitted | Will not latch, lock jammed |
| Windows open, stay open and lock; screens intact | Painted shut, broken balance, torn screen |
| A bedroom window that serves as the emergency way out | Blocked by fixed bars, a window air conditioner or furniture |
| Outlets, lights and closet | As in the living areas |
Heating, cooling and water heater
| Check | Fail if |
|---|---|
| Heat: run it until every room warms | A cold room; a burning smell that lasts; any doubt about a fuel-burning unit’s venting (call a licensed technician) |
| Cooling: supply air clearly cooler than the room | Warm air, ice on the lines, a noisy fan |
| Filter replaced, with the date written on the frame | Old filter still in, or no date on the new one |
| Condensate drain and pan | Water standing in the pan, line clogged |
| Thermostat responds; batteries new | No response |
| Water heater in the unit: fittings, relief valve discharge pipe, the space around it | Rust or a drip at fittings, water in the pan, storage against it |
The HVAC maintenance checklist covers the full service on the building’s shared equipment.
Smoke and carbon monoxide alarms
| Check | Fail if |
|---|---|
| Each smoke alarm: press the test button; read the date of manufacture on the back | No sound, missing where one was, or over 10 years old |
| Each carbon monoxide alarm, in units with fuel-burning appliances or an attached garage | No sound, or past the end-of-life date on its label |
| Test written down: date, unit, alarm, who tested | Not recorded |
Windows, doors and locks
| Check | Fail if |
|---|---|
| Every window: lock, balance, screen, glass | Cracked glass, missing lock (a fogged double pane is cosmetic: note it) |
| Patio or balcony door: slides, locks, security bar | Will not lock |
| Balcony railing | Loose post or rail, gaps wider than your building code allows |
| Exterior door locks rekeyed or cylinders changed; new keys and mailbox key logged | An old key still works |
Final walk
| Check | Fail if |
|---|---|
| Every line above passed, or has an open work order with a date | Any open safety item |
| Clean throughout, including inside appliances, cabinets, light fixtures and window tracks | Dust, grease, debris |
| Photos of every room for the move-in record | Missing |
| Utilities on, thermostat set, hot water at the taps | Anything off |
| Keys, fobs and remotes counted | Count short |
| Signed off by someone who did not do the work | Signed by the technician |
A typical turn, day by day
The order matters more than the day count: repairs before paint, paint before floors, floors before cleaning, so nothing is done twice.
ExampleA standard make ready over 3 to 5 days
| Day | Work | Who |
|---|---|---|
| Before move-out | Pre-move-out walk; order parts; book painter, carpet cleaner and cleaners | Supervisor |
| Day 0, keys back | Move-out inspection with photos of every room; scope list written; utilities on | Supervisor or manager |
| Day 1 | Trash-out; repairs to plumbing, electrical, doors, drywall and appliances; HVAC filter | Technician |
| Day 2 | Paint: touch-up or full | Technician or painter |
| Day 3 | Flooring: carpet cleaned or replaced, hard floors repaired | Vendor |
| Day 4 | Cleaning; alarms tested; locks rekeyed | Cleaners and technician |
| Day 5 | Final walk against this list; open items closed; unit marked ready | Someone other than the technician |
A light turn folds days 2 and 3 into one. A heavy one, with new flooring or cabinets, runs longer.
Before you start
When a check fails
Fix it before the next step in the sequence, or write a work order for anything that needs a part or a vendor. A safety fail (an alarm, a GFCI outlet, a gas appliance, the range’s anti-tip bracket, a lock) keeps the unit off the market until it is fixed.
Gas, electrical panel and refrigerant work goes to a licensed technician.
What the rules say about alarms, locks and lead paint
In some places, testing the alarms and rekeying the locks at every turnover is the law. In housing built before 1978, EPA’s lead paint rule sets how much paint a make ready may disturb without a certified firm.
What the rules sayAlarm tests in Texas, Ontario and HUD housing, rekeying in Texas, and EPA's lead rule.
- Smoke alarms in Texas. Texas Property Code section 92.258 requires the landlord to test the smoke alarm at the beginning of each tenant’s possession.
- Ontario. Ontario’s Fire Code has landlords test smoke and carbon monoxide alarms every year and after every change of tenancy, and keep a written record.
- Replacing alarms. The U.S. Fire Administration advises replacing smoke alarms every 10 years.
- HUD housing. HUD-assisted properties are inspected against the smoke and carbon monoxide alarm standards in HUD’s NSPIRE standards.
- Everywhere else. Other states, provinces and cities have their own rules on where alarms go and who tests them; check yours, and test each alarm the way its maker’s instructions say.
- Rekeying in Texas. Texas Property Code section 92.156 requires a security device operated by a key, card or combination to be rekeyed within 7 days after each tenant turnover. Rekeying at every turn is good practice everywhere.
- Lead paint. In housing built before 1978, EPA’s lead renovation, repair and painting rule applies to work that disturbs more than 6 square feet of paint in a room (20 square feet outside), and to any window replacement: those are the limits of “minor repair and maintenance” in 40 CFR 745.83.
- Who may do that work. It needs an EPA or state certified firm and certified renovators using lead-safe practices, and EPA says the rule covers in-house maintenance staff as well as outside contractors.
This is information, not legal advice; your state may run its own lead program.
Turnovers in Maintensor: one procedure, a new work order each time
Maintensor has no ready-made checklists, so build this one once as a procedure: a Heading step for each room, then an Inspection check (Pass, Flag or Fail) for each line. Make each apartment a location inside its building, and for each turnover create a work order on the unit with the procedure attached.
- Readings. Add a Number step for the refrigerator temperature, with the limit in the step’s name (“Fridge °F, pass at 40 or below”), since a Number step has no units or limits of its own.
- The final walk. A Photo step per room for the move-in record, and a Signature step. It keeps the drawn signature and the time but not who drew it, so put a Text step for the walker’s name beside it.
- A Fail. The technician adds a note and a photo before moving on and is offered a follow-up work order, for the carpet vendor or a part on order. Required steps left open are listed at sign-off and written to the work order’s history.

What it does not do: there are no work order templates and no way to copy a work order, so each turnover is a new work order, but the procedure carries every step, and a change to the list is published once as a new version.
Only Admins and Full users answer checklists, so the technician and the walker each need a user seat; a vendor’s painter does not.
The yearly alarm test in occupied units is a separate work order that repeats each year; the apartment maintenance checklist puts it with the building’s other rounds. The facility maintenance software page covers running a building; the property maintenance guide covers requests, vendors and a 120-unit worked example.